PID ToF Session at CM XXX.

Europe/Berlin
Minutes of the PID-TOF meeting, Tuesday, 8th September, 2009 The meeting was led by Lars Schmitt, since Carsten Schwarz participated due to an experiment at GSI by EVO. Vladimir Vikhrov, PNPI St.Petersburg, TOF-TOF correlations and PID. Vladimir simulated with Pythia and Geant3 the Channel pbar p --> Lambda Lambdabar X at 15 GeV. Since there is not start counter the PID can only be performed by relative timing. He studied the relative time between different TOF counters. These counters were the barrel-TOF, the forward-TOF and the left and right forward-TOF within the Dipole gap. Alexander Akindinov, ITEP Moscow, Progress in Panda TAG-TOF development by ITEP group. Alexander showed the status and plans of an RPC prototype for PANDA. Since the noise for an 2.5x3.5 cm2 pad at Alice dropped to 1Hz, it is possible to use the RPC barrel as a fast trigger on eg. 3 charged particles. He showed the mechanical setup of the counters and details of the attached electronic boards. The PANDA-Root model is in preparation. Bernhard Roth, RU-Bochum, Studies for barrel TOF with phi phi pi0. Bernhard has chosen a channel of a possible glueball candidate, which has low energetic kaons in the final state. As background channel he used pbar p --> K+ K- pi+ pi- pi0. Assuming that all charged particles are kaons and neglecting any PID he gets an background suppression of 10^7. He only uses the EMC informations for the pi0, the remaining constraints are given by the beam momentum of this formation channel. He concludes, that no barrel TOF is necessary for this channel. Vladimir Gapienko, IHEP Protvino, IHEP+JINR activity for barrel TOF in 2008-2009. Vladimir showed an RPC-TOF with double sided strip readout. For an 4 gap counter the radiation thickness is about 6% including FEE and cables. A 6 gap counter with 0.6mm glass plates ammounts to 7% radiation length. From a test experiment in 2008 the time resolution of the 6 gap counters is shown to be sigma ~ 50ps. For double sided readout the position resolution along the strip is 1cm. It was stated, that despite the progress on software and hardware many items are missing (eg. physics case) which allow to decide if a barrel TOF is desired or undesired.
There are minutes attached to this event. Show them.
    • 09:00 09:20
      TOF barrel -TOF wall correlations in PID 20m
      Speaker: Vladimir Vikhrov, PNPI St.Petersburg
      Slides
    • 09:20 09:35
      Barrel RPC counter 15m
      Speaker: Alexander Akindinov, ITEP Moscow
      Slides
    • 09:35 10:00
      Barrel TOF and Phi-Phi-Pi0 analysis 25m
      Speaker: Bernhard Roth, RU-Bochum
      Slides
    • 10:00 10:15
      IHEP/JINR activity on RPC barrel TOF 15m
      Speaker: Vladimir Gapienko (IHEP Protvino)
      Slides