Performance of the Prototype Gas Recirculation System with built-in RGA for INO RPC system

12 Feb 2010, 11:30
20m
Hörsaal GSI (GSI Helmholtzzentrum für Schwerionenforschung GmbH)

Hörsaal GSI

GSI Helmholtzzentrum für Schwerionenforschung GmbH

Planckstr. 1 64291 Darmstadt Germany

Speaker

Mr Suresh Kalmani (TIFR, Mumbai)

Description

An open loop gas recovery and recirculation system has been developed for the INO RPC system. The gas gas mixture coming from RPC exhaust is first desiccated by passing through molecular sieve (3Å + 4Å). Subsequent srubbing over basic active alumina removes toxic and acidic contaminants. The Isobutane and Freon are then separated by diffusion and liquefied by fractional condensation by cooling upto -26 ℃. A residual Gas Analyser (RGA) is being used in the loop to study the performance of the recirculation system. The results of the RGA analysis will be discussed.

Primary author

Mr Suresh Kalmani (TIFR, Mumbai)

Presentation Materials